Javeline Technical Systems Sp. z o.o., is an experienced, independent company with a global network of partners. We provide comprehensive services dedicated to process engineering, ranging from design, construction and commissioning of control & measurement systems that utilize the highest quality, commercially-available devices. Our systems are designed primarily with analyzers that are based on IR spectroscopy and mass spectrometry (quadrupole and magnetic sector technologies). We operate in sectors such as:
- petrochemical
- biofuel production
- chemical
- pharmaceutical
- food and beverages
- metals, minerals & mining
- environmental and atmospheric research
- gas analysis
- nanotechnologies
- research and development activities
- processes in cement industry
- and many others
We specialize in the design of turn-key systems wherein we co-bundle individual analyzers with a sampling pre-conditioning system which are collectively integrated into a common, temperature-controlled system enclosure. In order to ensure the highest quality of services and products offered, all system components are rigorously tested in terms of their usability, integrity, stability, quality and safety.

Our systems are configured to operate under extreme and challenging conditions. Such as being able to receive sample gases from a steel furnace operating at a vacuum of 1 Torr or for petrochemical-related applications where the sample take-off pressure can reach upwards of 400 bar(g). The JTS-designed sampling conditioning systems are made of 316SS, 6MO, titanium, GRP, CR22 materials and others corresponding to the NACE, NORSOK and PED standards. If necessary, the gas supply lines and the system are heated up to 130 ° C in order prevent the sample gas from condensing. By maintaining the sample gas above its dewpoint, we can ensure trouble-free operation and maximize system up-time. We can also provide systems which are designed to sample from many measuring points on a sequenced basis. Based upon the sample conditions present, we can design our sample system to properly filter dust and other solid particles present in order to prevent loss-of-sample flow conditions. If required, compliance with ATEX regulations and their counterparts can be achieved by providing approved electro-mechanical components and by obtaining 3rd party system certification. When required, JTS can also certify its integrated systems scope of supply via a FAT (Factory Acceptance Testing) and/or SAT (Site Acceptance Testing). We work with our clients from the conceptual design stage and consult with them all the way through to the fulfillment of our obligations. And even longer ... We perfectly understand that our responsibility to our clients does not end when the control and measurement system installation is complete. Our mission requires that we continue our support efforts thereafter by providing technical assistance, further consultations and on-site services for as long as we are needed in order to ensure that our clients are completely satisfied with our performance.




The company Javeline Technical Systems is based on a global network of partnerships and agreements, it is built with the participation of the companies with global recognition and engaged in the production of the highest quality control and measurement equipment, as well as accompanying equipment, necessary to build the comprehensive measurement and analytical systems.
Our area of core activity is:
- selection, application, deployment, delivery and service of control and measurement equipment;
- technical consulting and support on control and measurement equipment;
- design, installation and commissioning of control, measurement and analytical systems;
- integration with control systems;

In addition to measuring and analytical systems for industrial and laboratory applications based on mass spectrometers utilizing quadrupole and magnetic sector technologies, we offer solutions using gas analyzers such as chemiluminescent analyzers, FTIR (Fourier transform infrared spectroscopy), NDIR (non-dispersive infrared spectrometry), analyzers PAS based on infrared photoacoustic spectroscopy, paramagnetic or electrochemical oxygen analyzers and also analyzers based on fluorescent technology (UVF) and acoustic method, as well as integrated systems (eg SRC catalytic reduction monitoring systems, monitoring systems for power boilers, landfill sites, emissions from motor vehicles) and special products. The supplier of the above-mentioned analyzers and integrated systems is California Analytical Instruments, Inc. (CAI) from California, USA. We decided to cooperate closely with this company because of the trust they have received from customers all over the world. Tens of thousands of analyzers sold to thousands of customers and the highest professionalism at every level of cooperation are the reasons that place California Analytical Instruments, Inc. (CAI) in the forefront of manufacturers of similar analyzers and accessories.
Founded in 1982, headquartered in Orange, CA, CAI provides gas analyzers and measuring systems for industrial, environmental, process, occupational safety and emission control applications from automotive vehicles. The key advantage of instruments and measurement systems offered by CAI is a precise analysis of virtually any gas. California Analytical Instruments offers not only technology, but also the best customer support in the industry.
Together with California Analytical Instruments, Inc. Javeline Technical Systems Ltd. is ready to provide optimal solutions for the most diverse analytical needs of a wide spectrum of recipients. In this also yours ...
Therefore, we invite you to cooperate ...



Since the company’s inception in 1992, CAI’s mission has been to provide innovative gas analysis solutions to meet the needs of our customers for years to come. Our current analyzers utilize proven technologies for a wide range of measurements, including:
Units dedicated to measuring the following gases:
CAI offers three analyzer models that utilize chemiluminescence technology for analyzing NO, NOX and NO2 concentrations within a gas sample.
The chemiluminescence method is used to measure the reaction between ozone and nitric oxide. In the NOX mode, the sample is routed through a converter. The resultant reaction is directly proportional to the total concentration of NOX. The reliability and rapid response time of CAI CLD analyzers make them particularly well-suited for the following applications:
- Continuous emissions monitoring (CEM)
- Vehicle emissions
- Scrubber efficiency
- Combustion efficiency
- Ammonia slip
- Process control
- Power plant de-nitrification
- Fuel cell analysis
CLD Analyzer Highlights
- Measure NO/NOX from 0 to 3,000 ppm full scale
- Rapid response time
- No vacuum pump required
- Lowest CO2 quench available
- Low-temperature vitreous carbon NOX converter with no ammonia interference
- Auto calibration and ranging
- Electronic proportional pressure control for sample and ozone flow
- Output options: voltage, 4-20 mA, RS-232 using AK Protocol and TCP/IP, Modbus
- CE Mark and ETL-listed – conforms to UL Standard 61010-1; certified to CAN/CSA C 22.2 STD 61010-1



Units dedicated to measuring the following gases:
CAI offers four analyzer models that utilize Fourier Transfer Infrared technology for measuring concentrations of multiple gases within a sample. CAI FTIR analyzers deliver fast, accurate analysis of virtually any gas that has an infrared absorption spectrum.
- 600 SC FTIR – Most IR-absorbing gases + short cell for higher concentration levels
- 700 FTIR – Most IR-absorbing gases at ppb and low-ppm levels
- 7000 FTIR – Most IR-absorbing gases at ppb and low-ppm levels
- 700 FTIR Heated Sampler – For optimal hot/wet sample handling
CAI FTIR analyzers are based on Fourier Transform Infrared Spectroscopy. Non-symmetrical gas phase molecules absorb IR light, causing the molecular bonds to stretch, bend or rotate. This absorption is used to measure and quantify several chemical components simultaneously. CAI FTIR analyzers are well-suited for a wide range of applications, including:
- Stack gases (CEM/MACT)
- Vehicle emissions
- Process control
- VOC abatement/scrubber efficiency
- Ammonia slip
- Gas purity
- Agricultural emissions
- Greenhouse gas
- Biomass/landfill gas
FTIR Analyzer Highlights
- Accurate analysis of IR-absorbing gases
- Measure 20+ gases simultaneously
- Low ppb to high % ranges
- No Liquid Nitrogen required
- Low acquisition and operating costs




Units dedicated to measuring the following gases:
CAI offers two analyzer models that use Non-Dispersive Infrared (NDIR) technology to measure the concentrations of IR-absorbing gases in a sample. The 700 and ZPA models utilize paramagnetic or fuel cell technology to measure Oxygen.
- 700 LX NDIR/O2 – Up to 3 IR channels or 2 IR channels + O2
- ZPA NDIR/O2 – Up to 4 IR channels (including SO2, NOX) + O2
CAI NDIR analyzers’ measurements are based on the infrared absorption characteristics of gases. Using a single infrared beam to measure gas concentrations, they deliver highly stable and reliable results. CAI NDIR analyzers are well-suited for a wide range of applications, including:
- Stack gases (CEM)
- Vehicle emissions
- Combustion efficiency
- Turbine/generator feedback control
- Process chemical gas analysis
- Fuel cell analysis
- Personnel safety
Series 700 NDIR/O2 Analyzer Highlights
- Accurate analysis of IR-absorbing gases
- Measure from low ppm to 100% full scale
- Rapid response time
- Internal sample pump
- Optional Model 600 P/F – Oxygen analyzer with no NDIR gases
ZPA NDIR/O2 Analyzer Highlights
- Up to four IR channels plus Oxygen
- Measures from low ppm to % concentrations
- One or two ranges per component
- Virtually unaffected by moisture interference
- Optional external NOX converter

Units dedicated to measuring the following gases:
CAI offers two dedicated analyzer options to measure oxygen. Either paramagnetic technology or the fuel cell method may be used to determine the percentage level of oxygen in the gas sample.
CAI Oxygen analyzers are a great fit for a wide range of applications, including:
- Stack gases (CEM)
- Vehicle emissions
- Combustion efficiency
- Turbine/generator feedback control
- Process chemical gas analysis
- Fuel cell analysis
CAI O2 Analyzer Highlights
- Paramagnetic or fuel cell detector
- Up to four user-definable ranges per channel
- Temperature stabilization (PMD)
- Pressure compensation (PMD)
- Measures O2 from 0-1% to 0-100%
- Dual-channel Oxygen analyzer available

Units dedicated to measuring the following gases:
CAI FID analyzers rely on the Flame Ionization Detection principle to measure the total concentration of hydrocarbons in a gas sample. The gas sample becomes ionized in the flame and the electrostatic field causes the charged particles to migrate, creating a small current that is measured by the amplifier. The current is directly proportional to the amount of hydrocarbon in the sample. The 700 MHFID model measures Total Hydrocarbon and provides a means of differentiating between Methane and non-Methane hydrocarbons.
CAI FID analyzers can measure THC or CH4 in ppm or percent levels. They are ideal for applications such as:
- VOC abatement/scrubber efficiency
- Combustion engine testing
- EPA Method 25A compliance monitoring
- Continuous emission monitoring (CEMs)
- Vehicle emissions
- Fermentation monitoring
- Carbon bed breakthrough detection
- Process gas analysis


Units dedicated to measuring the following applications:
GPA 2000 Series Gas Purity Analyzers utilize the speed of sound to accurately detect the concentration of one gas in the presence of another.
GPA 2000 software allows the end user to reconfigure the unit for a wide variety of different gas combinations, making it an ideal choice for gas cylinder filling operations. The GPA 2000 can applied in a variety of different applications:
- Verifying gas cylinder-filling operations for welding, diving, medical, laser and analyzer calibration gas mixtures.
- Verifying specialty gas blends used in the semiconductor industry (e.g. Formic Acid in N2).
- H2 purity analysis for turbine generators used in power plants.
- Verifying the N2 purity from nitrogen skid generators.
- Heat treating / annealing furnace applications (e.g. 10% H2 in N2).
- Gas purity analysis of H2 and O2 gases generated by large-scale electrolysis plants.
- Analysis of H2 purity from pressure swing absorption (PSA) units.
CAI Speed-of-Sound Gas Purity Analyzer Highlights
- Maintenance-free resonant acoustic sample cell (304SS).
- No need for field recalibration after factory-characterization of the RASC.
- No need for reference or calibration gases, no consumables, no GC columns, etc.
- Software allows the end user to select from a menu of over 500 different gases.
- Software allows the end user to remotely change the binary gas mixture of interest (e.g. from CO2 in N2 to H2 in He) with no need of recalibration.
- Software allows the end user to remotely start and stop the analysis, chart the analyzer’s output which can then be printed and used to support gas cylinder certification requirements.

Units dedicated to measuring the following applications:
CAI UVA 5000 Series Analyzers utilize the field-proven UV Absorbance method to continuously detect gas-phase compounds that are capable of absorbing UV light energy.
The UVA 5000 incorporates state-of-the-art optical components that are combined with fiber optics to provide highly accurate measurements in an extremely small, space-saving form factor. UVA 5000 analyzers can readily be applied in the following applications:
- Trace H2S analysis in natural gas / amine scrubbers or in biogas food digesters.
- Trace SO2 analysis in flue gas desulfurization (FGD).
- Chlorine feed gas monitoring.
- ClO2 analysis in the pulp and paper industry.
- % F2 analysis in UF6 / nuclear fuel processing.
- % NH3 analysis.
CAI UVA Analyzer Highlights
- Compact, space-saving configuration with no moving parts. Available for use in either hazardous or non-hazardous-rated areas.
- High-pressure-rated 316SS sample flow cell that is isolated from the controller electronics.
- Long-life, pulsed UV Xenon Flash lamp.
- Photomultiplier tube (PMT) detector provides a highly sensitive and stable measurement of the gas of interest.
- Touch-screen user interface provides diagnostic information vis-à-vis an automatic change in the concentration display color.

Systems dedicated to measuring the following gases:
CAI offers integrated stationary and mobile analysis systems that incorporate multiple measurement technologies into single packages. They are designed to serve a wide range of applications within many industries.
NOx + O2 in climate-controlled NEMA 4 or 4X enclosure

CO, CO2, O2, NOx, SO2, CH4 (Up to 5 Gases) in climate-controlled NEMA 4 or 4X enclosure

CO, CO2, O2, NOx, SO2, CH4 (Up to 3 Gases) in climate-controlled NEMA 4 or 4X Enclosure

CH4, CO2, O2 in climate-controlled NEMA 4 or 4X enclosure

CO, CO2, THC, NOx, O2

Devices dedicated for special use:
CAI offers a number of specialty products to augment our line of analyzers. The Zero Air Generator (ZAG) provides a pure source of zero air. The Pump Pak II gives analyzers an external sample pump. The 700 Gas Divider eliminates the need for multiple gas cylinders. The 700 Multipoint Sampler enables the programming of up to 16 sample lines. And the 700 FTIR Heated Sampler provides temperature control circuits for heated sample handling.






In 2019, California Analytical Instruments introduced a new family of analyzers dedicated to liquid phase applications. CAI liquid phase analyzers utilize proven fiber optic-based technology for a wide range of measurements, including:
CAI liquid analyzers dedicated to the following applications:
The CAI Model NIR 4000L utilizes the field-proven NIR Absorbance method to continuously detect water impurities found in solvents, acids, alcohols and glycols.
The NIR 4000L incorporates a tungsten halogen lamp, 2 x fiber-optic cables, a flow-cell and InGaAs photodiode detector. These state-of-the-art optical components combine to deliver a highly reliable, continuous measurement of water in the liquid-phase. The NIR 4000L can readily be applied in the following applications:
- 0-5% H2O in Ethylene Glycol.
- 0-1% H2O in Acetone.
- 0-1% Water in Methanol or Ethanol.
- 0-10% Water in Acetic Acid.
CAI NIR Analyzer Highlights
- Compact, space-saving configuration with no moving parts. Available for use in either hazardous or non-hazardous-rated areas.
- High-pressure rated 316SS sample flow cell that is isolated from the controller electronics.
- Optical design approach that compensates for source or detector aging.
- Two-stage, TE-cooled InGaAs photodiode detector provides a highly sensitive and stable measurement of water in a variety of different backgrounds.
- Touch-screen user interface provides diagnostic information vis-à-vis an automatic change in the concentration display color.

CAI liquid analyzers dedicated to the following applications:
The CAI Model UVA 5000L utilizes the field-proven UV Absorbance method to continuously detect liquid-phase compounds that are capable of absorbing UV light energy.
The UVA 5000L incorporates state-of-the-art optical components that are combined with fiber optics to provide highly accurate measurements in an extremely small, space-saving form factor. The UVA 5000L can readily be applied in the following applications:
- ASTM-SAYBOLT color analysis of petroleum products.
- Trace detection of aromatics (BTEX) in water.
- Trace chlorine-in-water detection.
- Sodium Hypochlorite (NaOCl) in spent caustic.
CAI UVA Analyzer Highlights
- Compact, space-saving configuration with no moving parts. Available for use in either hazardous or non-hazardous-rated areas.
- High-pressure rated 316SS sample flow cell that is isolated from the controller electronics. Long-Life, Pulsed UV Xenon flash lamp.
- Photomultiplier tube (PMT) detector provides a highly sensitive and stable measurement of the gas of interest.
- Touch-screen user interface provides diagnostic information vis-à-vis an automatic change in the concentration display color.

CAI liquid analyzers dedicated to the following applications:
The CAI Model UVF 5560L Oil-in-Water Analyzer utilizes the field-proven UV Fluorescence method to continuously detect the undesirable presence of oil in water.
The Front Surface UV Fluorescence Probe that is mated with the Model 5560L Controller via a pair of fiber-optic cables (i.e. excitation and emission) can either be installed directly into a process pipe or configured to continuously measure the oil-in-water content on an extractive basis.
The UVF 5560L can be applied in a variety of different applications:
- Oil in boiler return-steam condensate within a power generation facility.
- Oil in cooling-tower water for hydrocarbon leak detection purposes.
- Detecting the oil levels collected within a refinery sump pit prior to discharge to our waterways for environmental compliance purposes.
- Oil-in-water detection at gas-oil separators (GOSP) / gathering centers.
- Waste-water treatment plants (WWTP).
- The detection of oil in produced water from an offshore oil rig and FPSO for environmental compliance purposes.
CAI UVF Analyzer Highlights
- Compact, space-saving configuration with no moving parts. Available for use in either hazardous or non-hazardous-rated areas.
- Long-life, pulsed UV Xenon flash lamp.
- Photomultiplier tube (PMT) detector provides a highly sensitive and stable measurement of the oil in water.
- Process pipe insertion devices allow the Front Surface UVF Probe to be installed and safely removed from a process pipe under pressure.
- The UVF Probe is available in 316SS (Std) as well as other corrosion-resistant alloys.
- CAI provides fiber optic cables in flex-conduit to protect the fibers from being mishandled.


California Analytical Instruments, Inc. now has 30,000 analyzers in the field, monitoring emissions for Industrial, Environmental, Process and Automotive applications. Their product offering consists of both single-gas analyzers and those that measure multiple gases.
With thousands of customers using CAI analyzers for a variety of applications, the chances are good we are an ideal fit for yours.

Pharmaceutical industry and
medical equipment
- EtO and NO2 sterilization
- Solvents off–gassing
- Fermentation Process Control

Automotive
industry
- Vehicle exhaust measurements for Ammonia, Ethanol, Nitrous Oxide, CO2, CO and H2O
- Ammonia slip
- SHED testing for Methanol, Ethanol, Toluene, CO2, R-134-A and H2O

Industrial
gases
- Gas analysis
- Gas purity

Utilities and
power generation
- Turbine/generator feedback control
- Scrubber/combustion efficiency
- Ammonia slip
- Power plant de-nitrification
- Fuel cell analysis

Chemical and
petrochemical industry
- Monitoring and control of technological processes
- SHED testing for Methanol, Ethanol, Toluene, CO2, R-134-A and H2O

Cement
industry
- Optimization and control of:
kiln gas outlet, calciner, preheater, coal bin, coal mill;
- NH3 measurement

Food and beverages
industry
- Carbonating, CAS, MAP
- Preservation, Undercover gassing
- Freezing, Fermentation
- High pressure extraction

Metals
production
- Monitoring and control of technological processes

Applications in
agro-industry
- Agricultural emissions
- Biomass/landfill gas
- Saturated gas from lime kiln
in sugar production

Landfill
gases
- Monitoring of landfill gases
- Analysis of landfill gases (e.g. CO2 and CH4)




























































































*All product names, trademarks and registered trademarks are property of their respective owners. All company, product and service names used in this website are for identification purposes only. Use of these names, trademarks and brands does not imply endorsement.
We’re Hiring a Field Sales Engineers for CEE region
About the role:
We are pleased to propose an exciting opportunity for a Field Sales Engineer with the relevant experience and background who is looking for a role in which they can grow and progress, establishing their career with a company where hard work is recognised and rewarded. The Field Sales Engineer will play a key role in the expansion of our growing business, reaping the benefits of progression within a small team of dedicated professionals.
Key aspects of the Field Sales Engineer opportunity:
- Managing customer relationships and identifying opportunities to secure a new business;
- Planning and writing grants, monitoring and supervising contracts;
- Remote working with frequent customer site visits and the opportunity of travel within designated country/countries;
- Collaboration with a close team of like-minded professionals;
- Undertaking additional duties as may be assigned from time to time;
This role would suit a sales professional with great problem-solving skills and self-discipline. You will be solution orientated with sound judgement and good business and technical acumen.
There is the opportunity for the successful Technical Sales Engineer to progress within the business after proving themselves and play a pivotal role in the company's growth.
It is essential that the successful candidate has proven experience and education within the Process Industry/Process Control Instrumentation/Process Automation and has an excellent understanding of process applications. Technical training will be provided.
Key Responsibilities:
- Enquiry handling;
- Maintaining customer relations and business development;
- Assessing client’s needs and proposing relevant solutions;
- Project management;
- Assisting the Business Development Director EMEA and VP Sales with sales related activities;
- Occasional on-site work alongside our other professionals;
- Support sales team in day-to-day activities;
- Keeping the company database updated;
Person Specification:
The successful candidates will be professional, loyal, hard-working, self-motivated, and self-disciplined. They will have efficient communication skills and will show the ability to work predominantly remotely in a reliable and efficient manner.
The successful candidates will show excellent initiative and self-discipline, also showing the ability to work reliably in and independently whilst maintaining communications and collaborative efforts within a small team.
The Field Sales Engineers will be punctual and enthusiastic, demonstrating problem-solving skills, be organised and possess good time management skills. It is essential that the successful applicant have an engineering background and an existing of technical knowledge. An interest in, and a willingness to learn, the technical aspects of industrial processes are also desired.
Personal Requirements:
- Full driving licence;
- IT literate;
- Proficient user of Microsoft Office applications;
- Knowledge of chemometrics tools for use within the MATLAB® environment and Aspen HYSYS software will be an additional advantage;
- Team working ability;
- Profound technical background;
Key Interfaces:
- VP Sales, Business Development Director EMEA;
- Commercial & technical support;
- Business unit manager and different product managers;
Apply for this Vacancy:
If this role fits your personality and matches your skill sets, then please email us a covering letter and your CV on:
hr (at) javeline-ts.de